FLOW     LENGTH    
Nl/sNm³/min50 m100 m150 m300 m500 m750 m1000 m1300 m1600 m2000 m
30.220202020202025252525
80.520202525254040404040
140.825252540404040405050
191.225404040404050505050
281.740404040505050506363
422.540404050506363636363
69440505063636380808080
9765050636380808080100100
1398506363808080100100100100
2081363638080100100100158158158
27817638080100100158158158158158
34721808080100158158158158158158
417258080100100158158158158158158
4862980100100158158158158158158158
5563380100100158158158158158158200
69442100100158158158158158200200200
83350100158158158158158200200200200
97258100158158158158200200200200200
111167100158158158158200200200200200
125075158158158158158200200200200250
138983158158158158200200200200250250
152892158158158200200200200250250250
1667100158158158200200200200250250250
            
Advised pipe diameters assume a straight line system with a compressor outlet temperature of 30°C and a maximum pressured drop of 5%.
For closed loop systems, flow rates can be doubled. (Example: 2000 m of 25 mm pipes in a closed loop system can achieve a 6 Nl/s flow at 4.5 bar.)
 FLOW     LENGTH    
Nl/sNm³/min50 m100 m150 m300 m500 m750 m1000 m1300 m1600 m2000 m
30.220202020202020202025
80.520202025252540404040
140.820202525404040404040
191.220252540404040404040
281.725254040404040505050
422.525404040405050505063
69440404050506363636363
97640405050636363808080
1398405050636380808080100
20813506363638080100100100100
278175063638080100100100100158
3472163638080100100100158158158
41725638080100100100158158158158
48629638080100100158158158158158
55633638080100158158158158158158
694428080100158158158158158158158
8335080100100158158158158158158158
9725880100100158158158158158200200
111167100100158158158158158200200200
125075100158158158158158200200200200
138983100158158158158158200200200200
152892100158158158158200200200200200
1667100100158158158158200200200200200
            
Advised pipe diameters assume a straight line system with a compressor outlet temperature of 30°C and a maximum pressured drop of 5%.
For closed loop systems, flow rates can be doubled. (Example: 2000 m of 25 mm pipes in a closed loop system can achieve a 6 Nl/s flow at 7 bar.)
 FLOW     LENGTH    
Nl/sNm³/min50 m100 m150 m300 m500 m750 m1000 m1300 m1600 m2000 m
30.220202020202020202020
80.520202020202525252540
140.820202025252540404040
191.220202525404040404040
281.720252540404040404040
422.525252540404040505050
69440404040505050506363
97640404050506363636363
139840404050636363808080
20813405050636380808080100
2781750506380808080100100100
347215063638080100100100100100
417255063638080100100100158158
4862963638080100100100158158158
5563363638080100100158158158158
69442638080100100158158158158158
83350808080100158158158158158158
972588080100100158158158158158158
11116780100100158158158158158158158
12507580100100158158158158158158200
13898380100100158158158158158200200
15289280100158158158158158200200200
1667100100100158158158158158200200200
            
Advised pipe diameters assume a straight line system with a compressor outlet temperature of 30°C and a maximum pressured drop of 5%.
For closed loop systems, flow rates can be doubled. (Example: 2000 m of 20 mm pipes in a closed loop system can achieve a 6 Nl/s flow at 10 bar.)
 FLOW     LENGTH    
Nl/sNm³/min50 m100 m150 m300 m500 m750 m1000 m1300 m1600 m2000 m
30.220202020202020202020
80.520202020202025252525
140.820202020252525404040
191.220202025254040404040
281.720202525404040404040
422.520252540404040404050
69425404040405050505050
97640404040505050636363
139840404050506363638080
2081340405050636363808080
27817405050636380808080100
3472150506363808080100100100
41725506363808080100100100100
486295063638080100100100100158
556335063638080100100100158158
6944263638080100100100158158158
83350638080100100158158158158158
97258638080100100158158158158158
111167808080100158158158158158158
1250758080100158158158158158158158
1389838080100158158158158158158158
15289280100100158158158158158158158
166710080100100158158158158158158158
            
Advised pipe diameters assume a straight line system with a compressor outlet temperature of 30°C and a maximum pressured drop of 5%.
For closed loop systems, flow rates can be doubled. (Example: 2000 m of 20 mm pipes in a closed loop system can achieve a 6 Nl/s flow at 13 bar.)
 FLOW     LENGTH    
Nl/sNm³/min50 m100 m150 m300 m500 m750 m1000 m1300 m1600 m2000 m
30.220202020202020202020
80.520202020202020202525
140.820202020202525252540
191.220202020252525404040
281.720202025254040404040
422.520202540404040404040
69425254040404040505050
97625404040405050505063
139840404040505063636363
2081340404050636363638080
2781740505063636380808080
34721405050636380808080100
417255050636380808080100100
4862950506363808080100100100
55633506363808080100100100100
694425063638080100100100158158
8335063638080100100100158158158
97258638080100100100158158158158
111167638080100100158158158158158
125075638080100100158158158158158
1389838080100100158158158158158158
1528928080100100158158158158158158
16671008080100100158158158158158158
            
Advised pipe diameters assume a straight line system with a compressor outlet temperature of 30°C and a maximum pressured drop of 5%.
For closed loop systems, flow rates can be doubled. (Example: 2000 m of 20 mm pipes in a closed loop system can achieve a 6 Nl/s flow at 16 bar.)