| Â | FLOW | Â | Â | Â | Â | Â | LENGTH | Â | Â | Â | Â |
| Nl/s | Nm³/min | 50 m | 100 m | 150 m | 300 m | 500 m | 750 m | 1000 m | 1300 m | 1600 m | 2000 m |
| 3 | 0.2 | 20 | 20 | 20 | 20 | 20 | 20 | 25 | 25 | 25 | 25 |
| 8 | 0.5 | 20 | 20 | 25 | 25 | 25 | 40 | 40 | 40 | 40 | 40 |
| 14 | 0.8 | 25 | 25 | 25 | 40 | 40 | 40 | 40 | 40 | 50 | 50 |
| 19 | 1.2 | 25 | 40 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | 50 |
| 28 | 1.7 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 63 | 63 |
| 42 | 2.5 | 40 | 40 | 40 | 50 | 50 | 63 | 63 | 63 | 63 | 63 |
| 69 | 4 | 40 | 50 | 50 | 63 | 63 | 63 | 80 | 80 | 80 | 80 |
| 97 | 6 | 50 | 50 | 63 | 63 | 80 | 80 | 80 | 80 | 100 | 100 |
| 139 | 8 | 50 | 63 | 63 | 80 | 80 | 80 | 100 | 100 | 100 | 100 |
| 208 | 13 | 63 | 63 | 80 | 80 | 100 | 100 | 100 | 158 | 158 | 158 |
| 278 | 17 | 63 | 80 | 80 | 100 | 100 | 158 | 158 | 158 | 158 | 158 |
| 347 | 21 | 80 | 80 | 80 | 100 | 158 | 158 | 158 | 158 | 158 | 158 |
| 417 | 25 | 80 | 80 | 100 | 100 | 158 | 158 | 158 | 158 | 158 | 158 |
| 486 | 29 | 80 | 100 | 100 | 158 | 158 | 158 | 158 | 158 | 158 | 158 |
| 556 | 33 | 80 | 100 | 100 | 158 | 158 | 158 | 158 | 158 | 158 | 200 |
| 694 | 42 | 100 | 100 | 158 | 158 | 158 | 158 | 158 | 200 | 200 | 200 |
| 833 | 50 | 100 | 158 | 158 | 158 | 158 | 158 | 200 | 200 | 200 | 200 |
| 972 | 58 | 100 | 158 | 158 | 158 | 158 | 200 | 200 | 200 | 200 | 200 |
| 1111 | 67 | 100 | 158 | 158 | 158 | 158 | 200 | 200 | 200 | 200 | 200 |
| 1250 | 75 | 158 | 158 | 158 | 158 | 158 | 200 | 200 | 200 | 200 | 250 |
| 1389 | 83 | 158 | 158 | 158 | 158 | 200 | 200 | 200 | 200 | 250 | 250 |
| 1528 | 92 | 158 | 158 | 158 | 200 | 200 | 200 | 200 | 250 | 250 | 250 |
| 1667 | 100 | 158 | 158 | 158 | 200 | 200 | 200 | 200 | 250 | 250 | 250 |
| Â | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â |
| Advised pipe diameters assume a straight line system with a compressor outlet temperature of 30°C and a maximum pressured drop of 5%. | |||||||||||
| For closed loop systems, flow rates can be doubled. (Example: 2000 m of 25 mm pipes in a closed loop system can achieve a 6 Nl/s flow at 4.5 bar.) | |||||||||||
| Â | FLOW | Â | Â | Â | Â | Â | LENGTH | Â | Â | Â | Â |
| Nl/s | Nm³/min | 50 m | 100 m | 150 m | 300 m | 500 m | 750 m | 1000 m | 1300 m | 1600 m | 2000 m |
| 3 | 0.2 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 25 |
| 8 | 0.5 | 20 | 20 | 20 | 25 | 25 | 25 | 40 | 40 | 40 | 40 |
| 14 | 0.8 | 20 | 20 | 25 | 25 | 40 | 40 | 40 | 40 | 40 | 40 |
| 19 | 1.2 | 20 | 25 | 25 | 40 | 40 | 40 | 40 | 40 | 40 | 40 |
| 28 | 1.7 | 25 | 25 | 40 | 40 | 40 | 40 | 40 | 50 | 50 | 50 |
| 42 | 2.5 | 25 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 63 |
| 69 | 4 | 40 | 40 | 40 | 50 | 50 | 63 | 63 | 63 | 63 | 63 |
| 97 | 6 | 40 | 40 | 50 | 50 | 63 | 63 | 63 | 80 | 80 | 80 |
| 139 | 8 | 40 | 50 | 50 | 63 | 63 | 80 | 80 | 80 | 80 | 100 |
| 208 | 13 | 50 | 63 | 63 | 63 | 80 | 80 | 100 | 100 | 100 | 100 |
| 278 | 17 | 50 | 63 | 63 | 80 | 80 | 100 | 100 | 100 | 100 | 158 |
| 347 | 21 | 63 | 63 | 80 | 80 | 100 | 100 | 100 | 158 | 158 | 158 |
| 417 | 25 | 63 | 80 | 80 | 100 | 100 | 100 | 158 | 158 | 158 | 158 |
| 486 | 29 | 63 | 80 | 80 | 100 | 100 | 158 | 158 | 158 | 158 | 158 |
| 556 | 33 | 63 | 80 | 80 | 100 | 158 | 158 | 158 | 158 | 158 | 158 |
| 694 | 42 | 80 | 80 | 100 | 158 | 158 | 158 | 158 | 158 | 158 | 158 |
| 833 | 50 | 80 | 100 | 100 | 158 | 158 | 158 | 158 | 158 | 158 | 158 |
| 972 | 58 | 80 | 100 | 100 | 158 | 158 | 158 | 158 | 158 | 200 | 200 |
| 1111 | 67 | 100 | 100 | 158 | 158 | 158 | 158 | 158 | 200 | 200 | 200 |
| 1250 | 75 | 100 | 158 | 158 | 158 | 158 | 158 | 200 | 200 | 200 | 200 |
| 1389 | 83 | 100 | 158 | 158 | 158 | 158 | 158 | 200 | 200 | 200 | 200 |
| 1528 | 92 | 100 | 158 | 158 | 158 | 158 | 200 | 200 | 200 | 200 | 200 |
| 1667 | 100 | 100 | 158 | 158 | 158 | 158 | 200 | 200 | 200 | 200 | 200 |
| Â | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â |
| Advised pipe diameters assume a straight line system with a compressor outlet temperature of 30°C and a maximum pressured drop of 5%. | |||||||||||
| For closed loop systems, flow rates can be doubled. (Example: 2000 m of 25 mm pipes in a closed loop system can achieve a 6 Nl/s flow at 7 bar.) | |||||||||||
| Â | FLOW | Â | Â | Â | Â | Â | LENGTH | Â | Â | Â | Â |
| Nl/s | Nm³/min | 50 m | 100 m | 150 m | 300 m | 500 m | 750 m | 1000 m | 1300 m | 1600 m | 2000 m |
| 3 | 0.2 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 |
| 8 | 0.5 | 20 | 20 | 20 | 20 | 20 | 25 | 25 | 25 | 25 | 40 |
| 14 | 0.8 | 20 | 20 | 20 | 25 | 25 | 25 | 40 | 40 | 40 | 40 |
| 19 | 1.2 | 20 | 20 | 25 | 25 | 40 | 40 | 40 | 40 | 40 | 40 |
| 28 | 1.7 | 20 | 25 | 25 | 40 | 40 | 40 | 40 | 40 | 40 | 40 |
| 42 | 2.5 | 25 | 25 | 25 | 40 | 40 | 40 | 40 | 50 | 50 | 50 |
| 69 | 4 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 63 | 63 |
| 97 | 6 | 40 | 40 | 40 | 50 | 50 | 63 | 63 | 63 | 63 | 63 |
| 139 | 8 | 40 | 40 | 40 | 50 | 63 | 63 | 63 | 80 | 80 | 80 |
| 208 | 13 | 40 | 50 | 50 | 63 | 63 | 80 | 80 | 80 | 80 | 100 |
| 278 | 17 | 50 | 50 | 63 | 80 | 80 | 80 | 80 | 100 | 100 | 100 |
| 347 | 21 | 50 | 63 | 63 | 80 | 80 | 100 | 100 | 100 | 100 | 100 |
| 417 | 25 | 50 | 63 | 63 | 80 | 80 | 100 | 100 | 100 | 158 | 158 |
| 486 | 29 | 63 | 63 | 80 | 80 | 100 | 100 | 100 | 158 | 158 | 158 |
| 556 | 33 | 63 | 63 | 80 | 80 | 100 | 100 | 158 | 158 | 158 | 158 |
| 694 | 42 | 63 | 80 | 80 | 100 | 100 | 158 | 158 | 158 | 158 | 158 |
| 833 | 50 | 80 | 80 | 80 | 100 | 158 | 158 | 158 | 158 | 158 | 158 |
| 972 | 58 | 80 | 80 | 100 | 100 | 158 | 158 | 158 | 158 | 158 | 158 |
| 1111 | 67 | 80 | 100 | 100 | 158 | 158 | 158 | 158 | 158 | 158 | 158 |
| 1250 | 75 | 80 | 100 | 100 | 158 | 158 | 158 | 158 | 158 | 158 | 200 |
| 1389 | 83 | 80 | 100 | 100 | 158 | 158 | 158 | 158 | 158 | 200 | 200 |
| 1528 | 92 | 80 | 100 | 158 | 158 | 158 | 158 | 158 | 200 | 200 | 200 |
| 1667 | 100 | 100 | 100 | 158 | 158 | 158 | 158 | 158 | 200 | 200 | 200 |
| Â | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â |
| Advised pipe diameters assume a straight line system with a compressor outlet temperature of 30°C and a maximum pressured drop of 5%. | |||||||||||
| For closed loop systems, flow rates can be doubled. (Example: 2000 m of 20 mm pipes in a closed loop system can achieve a 6 Nl/s flow at 10 bar.) | |||||||||||
| Â | FLOW | Â | Â | Â | Â | Â | LENGTH | Â | Â | Â | Â |
| Nl/s | Nm³/min | 50 m | 100 m | 150 m | 300 m | 500 m | 750 m | 1000 m | 1300 m | 1600 m | 2000 m |
| 3 | 0.2 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 |
| 8 | 0.5 | 20 | 20 | 20 | 20 | 20 | 20 | 25 | 25 | 25 | 25 |
| 14 | 0.8 | 20 | 20 | 20 | 20 | 25 | 25 | 25 | 40 | 40 | 40 |
| 19 | 1.2 | 20 | 20 | 20 | 25 | 25 | 40 | 40 | 40 | 40 | 40 |
| 28 | 1.7 | 20 | 20 | 25 | 25 | 40 | 40 | 40 | 40 | 40 | 40 |
| 42 | 2.5 | 20 | 25 | 25 | 40 | 40 | 40 | 40 | 40 | 40 | 50 |
| 69 | 4 | 25 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 50 |
| 97 | 6 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | 63 | 63 | 63 |
| 139 | 8 | 40 | 40 | 40 | 50 | 50 | 63 | 63 | 63 | 80 | 80 |
| 208 | 13 | 40 | 40 | 50 | 50 | 63 | 63 | 63 | 80 | 80 | 80 |
| 278 | 17 | 40 | 50 | 50 | 63 | 63 | 80 | 80 | 80 | 80 | 100 |
| 347 | 21 | 50 | 50 | 63 | 63 | 80 | 80 | 80 | 100 | 100 | 100 |
| 417 | 25 | 50 | 63 | 63 | 80 | 80 | 80 | 100 | 100 | 100 | 100 |
| 486 | 29 | 50 | 63 | 63 | 80 | 80 | 100 | 100 | 100 | 100 | 158 |
| 556 | 33 | 50 | 63 | 63 | 80 | 80 | 100 | 100 | 100 | 158 | 158 |
| 694 | 42 | 63 | 63 | 80 | 80 | 100 | 100 | 100 | 158 | 158 | 158 |
| 833 | 50 | 63 | 80 | 80 | 100 | 100 | 158 | 158 | 158 | 158 | 158 |
| 972 | 58 | 63 | 80 | 80 | 100 | 100 | 158 | 158 | 158 | 158 | 158 |
| 1111 | 67 | 80 | 80 | 80 | 100 | 158 | 158 | 158 | 158 | 158 | 158 |
| 1250 | 75 | 80 | 80 | 100 | 158 | 158 | 158 | 158 | 158 | 158 | 158 |
| 1389 | 83 | 80 | 80 | 100 | 158 | 158 | 158 | 158 | 158 | 158 | 158 |
| 1528 | 92 | 80 | 100 | 100 | 158 | 158 | 158 | 158 | 158 | 158 | 158 |
| 1667 | 100 | 80 | 100 | 100 | 158 | 158 | 158 | 158 | 158 | 158 | 158 |
| Â | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â |
| Advised pipe diameters assume a straight line system with a compressor outlet temperature of 30°C and a maximum pressured drop of 5%. | |||||||||||
| For closed loop systems, flow rates can be doubled. (Example: 2000 m of 20 mm pipes in a closed loop system can achieve a 6 Nl/s flow at 13 bar.) | |||||||||||
| Â | FLOW | Â | Â | Â | Â | Â | LENGTH | Â | Â | Â | Â |
| Nl/s | Nm³/min | 50 m | 100 m | 150 m | 300 m | 500 m | 750 m | 1000 m | 1300 m | 1600 m | 2000 m |
| 3 | 0.2 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 |
| 8 | 0.5 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 25 | 25 |
| 14 | 0.8 | 20 | 20 | 20 | 20 | 20 | 25 | 25 | 25 | 25 | 40 |
| 19 | 1.2 | 20 | 20 | 20 | 20 | 25 | 25 | 25 | 40 | 40 | 40 |
| 28 | 1.7 | 20 | 20 | 20 | 25 | 25 | 40 | 40 | 40 | 40 | 40 |
| 42 | 2.5 | 20 | 20 | 25 | 40 | 40 | 40 | 40 | 40 | 40 | 40 |
| 69 | 4 | 25 | 25 | 40 | 40 | 40 | 40 | 40 | 50 | 50 | 50 |
| 97 | 6 | 25 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 63 |
| 139 | 8 | 40 | 40 | 40 | 40 | 50 | 50 | 63 | 63 | 63 | 63 |
| 208 | 13 | 40 | 40 | 40 | 50 | 63 | 63 | 63 | 63 | 80 | 80 |
| 278 | 17 | 40 | 50 | 50 | 63 | 63 | 63 | 80 | 80 | 80 | 80 |
| 347 | 21 | 40 | 50 | 50 | 63 | 63 | 80 | 80 | 80 | 80 | 100 |
| 417 | 25 | 50 | 50 | 63 | 63 | 80 | 80 | 80 | 80 | 100 | 100 |
| 486 | 29 | 50 | 50 | 63 | 63 | 80 | 80 | 80 | 100 | 100 | 100 |
| 556 | 33 | 50 | 63 | 63 | 80 | 80 | 80 | 100 | 100 | 100 | 100 |
| 694 | 42 | 50 | 63 | 63 | 80 | 80 | 100 | 100 | 100 | 158 | 158 |
| 833 | 50 | 63 | 63 | 80 | 80 | 100 | 100 | 100 | 158 | 158 | 158 |
| 972 | 58 | 63 | 80 | 80 | 100 | 100 | 100 | 158 | 158 | 158 | 158 |
| 1111 | 67 | 63 | 80 | 80 | 100 | 100 | 158 | 158 | 158 | 158 | 158 |
| 1250 | 75 | 63 | 80 | 80 | 100 | 100 | 158 | 158 | 158 | 158 | 158 |
| 1389 | 83 | 80 | 80 | 100 | 100 | 158 | 158 | 158 | 158 | 158 | 158 |
| 1528 | 92 | 80 | 80 | 100 | 100 | 158 | 158 | 158 | 158 | 158 | 158 |
| 1667 | 100 | 80 | 80 | 100 | 100 | 158 | 158 | 158 | 158 | 158 | 158 |
| Â | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â | Â |
| Advised pipe diameters assume a straight line system with a compressor outlet temperature of 30°C and a maximum pressured drop of 5%. | |||||||||||
| For closed loop systems, flow rates can be doubled. (Example: 2000 m of 20 mm pipes in a closed loop system can achieve a 6 Nl/s flow at 16 bar.) | |||||||||||